Shanghai Huapu Cable

Home > Product > YJV

    Flame retardant cable

    • Models:ZAYJV, ZBYJV, ZCYJV

    Product DescriptionFlame retardant cable can transfer the power under the normal conditions, when the fire, the flame of the cable is reduced or not spread by the flame along the line of the cable, an

    1. Detailed information
    • Product Description
      Flame retardant cable can transfer the power under the normal conditions, when the fire, the flame of the cable is reduced or not spread by the flame along the line of the cable, and the cable will not be the cause of the flame spreading, there is no halogen low –smoke flame retardant power cable in this kind of cable, the acid gas, smoke and toxic gases generated by the cable during the fire are significantly reduced in the combustion state, thus facilitating the evacuation of personnel.
      0.6/1KV flame retardant power cable is accordance with GB/T 12706-2008 is equivalent to (IEC 60502-1:2005), 26/35KV flame retardant power cable is accordance with GB/T 12706.3-2008.
      Except according with power cable national standard, the grade of flame retardant power cable is generally, the grade from high to low, divide ZA, ZB,ZC, ZA grade cable must pass GB/T 18380.33-2008( is equivalent to( IEC60754-2:1991 Amendment No:1-1997) , combustion experiments, ZB grade cable must pass GB/T18380.34-2008( is equivalent to IEC60332-3-24:2000) combustion experiments, the experimental result respectively is accordance with national standard GB/T19666-2005 « flame retardant cable general principle>, it has tender requirement of ZA,ZB,ZC.
      Free halogen and Low smoke power cable, except according with power cable national standard, the cable must pass GB/T 17650.2-1998(is equivalent to IEC60754-2:1991 Amendment No: 1:1997) acid experiment of cable, experiment result is accordance with national standard GB/T19666-2005 flame retardant cable general principle, it has requirement of free halogen, the cable must pass GB/T 17651.2-1998(s equivalent to IEC61034.2:1997) smoke intensity of cable, experiment result is accordance with national standard GB/T 19666-2005 flame retardant cable general principle, it has requirement of low smoking.

    • Operating characteristic
      1. Installation environment temperature ≥0℃
      2. The temperature of cable when the normal running PVC≤70℃  XLPE≤90℃。
      3. Max operating temperature of con, when cable short circuited (5s maximum duration): PVC≤160℃  XLPE≤250℃。
      4. Single cable: [20(D+d)±5%],mm